Ionic exchanger

CatControl 6

The CatControl 6 can be combined with transducers and conductivity sensors from other manufacturers. It is employed for continuous conductivity measurement before and after strongly acidic cation exchanger. The pH-value is calculated by means of determination of the differential conductivity in accordance with VGB guidelines.
The degree of exhaustion of the exchanger mass is determined in connection with the integrated flow control. The standardly integrated ventilation of the CatControl 6 ensures a bubble-free sample flow even in the start-up phase.
Each CatControl 6 is equipped with a relief valve, which provides a pressure relief in the case of a pressure build-up in the filter (e.g. by blocking of the free sample discharge).
At the CatControl 6 outlet, a check valve is provided with an opening pressure of 0.1 bar which prevents a running dry in direction of flow and rear ventilating of the filter.

Material of vessel: acrylic glass

Material of head: PET

Material of screw connections: Stainless steel 316

Medium: Water and other liquids

Max. temperature: 80°C

Max. pressure: 3 bar

Prescribed amount of resin: 1,5 liter

Connection: male connector for tube 6 mm at the sample inlet, hose 5x1,5 mm at the outlet

Ionic exchanger KA15PE / KA30PE

Ionic exchanger for the inclusion of ionic exchanger resin. The ionic exchanger is used as a measuring-technical exchanger for the determination of the corrected conductivity in connection with appropriate measuring equipment.

Material of vessel: Acryl
Material of head/floor: PP
Material of connections: PVC
Medium: Water and other liquids
Connections: Quick connection couplings
Volume of resin: 1.5 or 3.0 liters