Other accessories
Back-up stop RLS10
Back-up stop in media lines
closes under pressure against flow direction
and opens under pressure in flow direction
Material of the basic element:
Interior components:
Medium:
Temperature:
Connection:
Max. working pressure:
Stainless steel 316/ A276
Stainless steel 316/ A276 & stainless steel 17-4PH/ A564
Water and other neutral liquids
-196°C to 480°C
Welded connections for pipe 10x2
420 bar
Machine thermometer TH27
Temperature measurement in media and cooling water
Material of casing: Brass
Scale: °C
Temperature: 0°C - 70°C
Connection: M18x1.5 SW22 internal thread
Machine thermometer TH29
Temperature measurement in media and cooling water
Material of casing: Stainless steel
Scale: °C
Temperature: 0°C - 80°C
Connection: Union nut M18x1.5 SW22 internal thread
Magnetite seperator MA10E
Removal of extremely fine magnetite particles from the sample flow by means of an integrated permanent magnet.
Sample filter
We offer a great variety of sample filters. For more detailed information, our service personnel will be at your disposal.
Degassing chamber BT 10
The degassing chamber BT 10 was developed to remove gas/air bubbles from the sample water of the water/steam cycle.
Principle of operation:
The medium flows through the medium inlet into the degassing chamber.
Possibly contained gas/air bubbles rise up and escape to the discharge via the pressure control valve downstream of the chamber.